2 drive 0 - drive 4 control routines – Rockwell Automation MD65 EtherNet/IP Communication Module User Manual

Page 75

Advertising
background image

Using Multi-Drive Mode

8-11

8.6.2 Drive 0 - Drive 4 Control Routines

The following Drive Control routines provide status information
(Logic Status and Feedback), control (Logic Command and
Reference), and parameter read/write for each of the respective
drives.

Figure 8.6 – Main Routine (Continued)

This rung writes the output image to the scanner. The output image is as follows:

DriveOutputImage[0] and DriveOutputImage[1] = Drive 0 Logic Command and Reference

DriveOutputImage[2] and DriveOutputImage[3] = Drive 1 Logic Command and Reference

DriveOutputImage[4] and DriveOutputImage[5] = Drive 2 Logic Command and Reference

DriveOutputImage[6] and DriveOutputImage[7] = Drive 3 Logic Command and Reference

DriveOutputImage[8] and DriveOutputImage[9] = Drive 4 Logic Command and Reference

(Note the length of the COP instruction is "5" because the Destination address is a DINT)

6

Copy File

Source

DriveOutputImage[0]

Dest MultiDrive_Demo:O.Data[0]

Length

5

COP

This rung writes the output image to the scanner. The output image is as follows:

DriveOutputImage[0] and DriveOutputImage[1] = Drive 0 Logic Command and Reference

DriveOutputImage[2] and DriveOutputImage[3] = Drive 1 Logic Command and Reference

DriveOutputImage[4] and DriveOutputImage[5] = Drive 2 Logic Command and Reference

DriveOutputImage[6] and DriveOutputImage[7] = Drive 3 Logic Command and Reference

DriveOutputImage[8] and DriveOutputImage[9] = Drive 4 Logic Command and Reference

(Note the length of the COP instruction is "5" because the Destination address is a DINT)

(End)

Table 8.8 – Module Parameter Settings

Control Routine

Refer to...

Drive 0

Figure 8.7

Drive 1

Figure 8.8

Drive 2

Figure 8.9

Drive 3

Figure 8.10

Drive 4

Figure 8.11

Advertising