Viewing the Module Configuration

The parameters in table 4.6 provide information about how the
module is configured. You can view these parameters at any time.

4.9

Setting Web Features Access

By accessing the IP address set for the module using a web
browser, you can view the module’s web pages for information
about the module, the MD65 drive to which it is connected, and
other MDI devices connected to the drive such as OIMs, serial
modules, or other daisy-chained drives (when module is in Multi-
Drive mode). Additionally, the module can be configured to
automatically send e-mail messages to desired addresses when
selected drive faults occur or are cleared, and when the module
takes a communication or idle fault action. For more details on the
module’s web pages, refer to chapter 10.

By default, the module web pages are disabled.

Table 4.6 – Module Configuration Parameters

Number

Name Description

1

Mode

The mode in which the module is set:

Values
0 = Single drive operation
1 = Multi-Drive operation

16

EN Rate Act.

The data rate used by the module:

Values
0 = No Link
1 = 10M bits/sec full
2 = 10M bits/sec half
3 = 100M bits/sec full
4 = 100M bits/sec half

23

MDI I/O Act

Indicates the drives that are active in the Multi-Drive mode:

Bit Definitions
0 = Drive 0 Active
1 = Drive 1 Active
2 = Drive 2 Active
3 = Drive 3 Active
4 = Drive 4 Active

29

Web Enable

Indicates the setting of the Web Pages Switch (SW2) on the
module when the module was last reset:

Values
0 = Disabled
1 = Enabled