Rockwell Automation RECOMM-ENET EtherNet/IP Communications Module User Manual
Page 122
Advertising
![background image](/manuals/581604/122/background.png)
B-4
EtherNet/IP Communications Module
Sets the bytes of the gateway address.
Important: To set the gateway address using these parameters,
parameter 3 (BOOTP) must be set to Disabled.
Configures the network data rate and duplex mode at which the
module communicates. Updates EN Rate Act (17) after reset.
12
13
14
15
Gateway Cfg 1
Gateway Cfg 2
Gateway Cfg 3
Gateway Cfg 4
Range:
0 to 255
Default:
0
Type:
Read/Write
Reset Required: Yes
255 . 255 . 255 . 255
Gateway Cfg 1
Gateway Cfg 2
Gateway Cfg 3
Gateway Cfg 4
16
EN Rate Cfg
Range:
0 = Autodetect
1 = 10 Mbps Full
2 = 10 Mbps Half
3 = 100 Mbps Full
4 = 100 Mbps Half
Default:
0 = Autodetect
Type:
Read/Write
Reset Required: Yes