Rockwell Automation RECOMM-ENET EtherNet/IP Communications Module User Manual

Page 151

Advertising
background image

EtherNet I/P Objects

C-15

Important:

If CIP messaging is available, use the CIP Parameter
object to get and set parameters.

N41:0
N41:1
N41:2
N41:3
N41:4
N41:5
N41:6
N41:7
N41:8
N41:9
N41:10
N41:11
N41:12
N41:13
N41:14
N41:15
N41:16
N41:17
N41:18

Logic Command Word
Reference (least significant word)
Reference (most significant word)
Datalink A1 (least significant word)
Datalink A1 (most significant word)
Datalink A2 (least significant word)
Datalink A2 (most significant word)
Datalink B1 (least significant word)
Datalink B1 (most significant word)
Datalink B2 (least significant word)
Datalink B2 (most significant word)
Datalink C1 (least significant word)
Datalink C1 (most significant word)
Datalink C2 (least significant word)
Datalink C2 (most significant word)
Datalink D1 (least significant word)
Datalink D1 (most significant word)
Datalink D2 (least significant word)
Datalink D2 (most significant word)

Logic Status Word
Feedback (least significant word)
Feedback (most significant word)
Datalink A1 (least significant word)
Datalink A1 (most significant word)
Datalink A2 (least significant word)
Datalink A2 (most significant word)
Datalink B1 (least significant word)
Datalink B1 (most significant word)
Datalink B2 (least significant word)
Datalink B2 (most significant word)
Datalink C1 (least significant word)
Datalink C1 (most significant word)
Datalink C2 (least significant word)
Datalink C2 (most significant word)
Datalink D1 (least significant word)
Datalink D1 (most significant word)
Datalink D2 (least significant word)
Datalink D2 (most significant word)

N42

This N-file lets you read and write some values configuring the port

N42:3

Time-out (read/write): Time (in seconds) allowed between messages to the N41
file. If the module does not receive a message in the specified time, it performs
the fault action configured in its Comm Flt Action parameter.

N42:7

Module Port Number (read only): DPI port on the drive to which the module is
connected.

N42:8

Peer Modules (read only): Bit field of devices having DPI Peer capabilities.

N-File

Description

N150 – N199 These N-files let you read and write parameter values in the DPI Host (for

example, an SP600 drive) as 32-bit double words. You can interpret the data
in various ways (for example, 32-bit real, 32-bit integer) To read a parameter,
you need to send a message with two elements. For example, to read
parameter 1, read two elements beginning at N150:2. As another example, to
read parameters 2 - 6, read ten elements beginning at N150:4.

N150:0 – 1
N150:2 – 249
N151:0 – 249
N152:0 – 249
N153:0 – 249

Number of parameters in the drive
Drive parameters 1 – 124
Drive parameters 125 – 249
Drive parameters 250 – 374
Drive parameters 375 – 499

...

...

N199:0 – 249 Drive parameters 6125 – 6249