C.12 dpi time object – Rockwell Automation RECOMM-ENET EtherNet/IP Communications Module User Manual
Page 167

EtherNet I/P Objects
C-31
C.12 DPI Time Object
Class Code
Instances
The number of instances depends on the number of timers in the
device. Instance 1 is always reserved for a real time clock although
a device may not support it. The total number of timers can be read
in Instance 0, Attribute 2.
Class Attributes
Hexadecimal
Decimal
0x9B
155
Instances (Hex)
(Dec)
Device
Example
Description
0x0000-0x3FFF 0-16383
Host
0
Class Attributes (Drive)
0x4000-0x43FF
16384-17407 Module
1
Real Time Clock
(Predefined) Not always
supported
0x4400-0x47FF
17408-18431 DPI Port 1
2
Timer 1
0x4800-0x4BFF 18432-19455 DPI Port 2
3
Timer 2
0x4C00-0x4FFF 19456-20479 DPI Port 3
...
...
0x5000-0x53FF
20480-21503 DPI Port 4
0x5400-0x57FF
21504-22527 DPI Port 5
0x5800-0x5BFF 22528-23551 DPI Port 6
Attribute
ID
Access
Rule
Name
Data
Type
Description
1
Get
Class Revision
WORD
Revision of object
2
Get
Number of
Instances
WORD
Number of timers in the object,
excluding the real time clock that is
predefined
3
Get
First Device
Specific Timer
WORD
Instance of the first timer that is not
predefined
4
Set
Time Command
Write
BYTE
0 = No operation
1 = Clear all timers (Does not clear
the real time clock or read-only
timers)