EtherNet I/P Objects
C-21
Instance Attributes
4
Get
NVS Link
Value
Checksum
WORD
Checksum of parameter links in a user set
in NVS
5
Get
First
Accessible
Parameter
WORD
First parameter available if parameters are
protected by passwords. A “0” indicates all
parameters are protected.
7
Get
Class
Revision
WORD
2 = DPI
8
Get
First
Parameter
Processing
Error
WORD
The first parameter that has been written
with a value outside of its range. A “0”
indicates no errors.
9
Set
Link
Command
BYTE
0 = No operation
1 = Clear all parameter links (This does not
clear links to function blocks.)
Attribute
ID
Access
Rule
Name
Data Type
Description
Attribute
ID
Access
Rule
Name
Data Type
Description
7
Get
DPI Online
Read Full
STRUCT of
BOOL[32]
CONTAINER
1
CONTAINER
CONTAINER
CONTAINER
WORD
WORD
STRING[4]
UINT
UINT
UINT
INT
BYTE[3]
BYTE
STRING[16]
Descriptor (refer to pages C-24 to
C-25)
Parameter value
Minimum value
Maximum value
Default value
Next parameter
Previous parameter
Units (e.g., amp, Hz)
Multiplier
2
Divisor
2
Base
2
Offset
2
Link (source of the value) (0 = no link)
Always zero (0)
Parameter name
8
Get
DPI
Descriptor
BOOL[32]
Descriptor (refer to pages
C-24 to C-25
9
Get/Set DPI
Parameter
Value
Various
Parameter value in NVS
3
10
Get/Set DPI RAM
Parameter
Value
Various
Parameter value in temporary
memory