Rockwell Automation RECOMM-ENET EtherNet/IP Communications Module User Manual

Page 157

Advertising
background image

EtherNet I/P Objects

C-21

Instance Attributes

4

Get

NVS Link
Value
Checksum

WORD

Checksum of parameter links in a user set
in NVS

5

Get

First
Accessible
Parameter

WORD

First parameter available if parameters are
protected by passwords. A “0” indicates all
parameters are protected.

7

Get

Class
Revision

WORD

2 = DPI

8

Get

First
Parameter
Processing
Error

WORD

The first parameter that has been written
with a value outside of its range. A “0”
indicates no errors.

9

Set

Link
Command

BYTE

0 = No operation
1 = Clear all parameter links (This does not

clear links to function blocks.)

Attribute

ID

Access

Rule

Name

Data Type

Description

Attribute

ID

Access

Rule

Name

Data Type

Description

7

Get

DPI Online
Read Full

STRUCT of
BOOL[32]
CONTAINER

1

CONTAINER
CONTAINER
CONTAINER
WORD
WORD
STRING[4]
UINT
UINT
UINT
INT
BYTE[3]
BYTE
STRING[16]

Descriptor (refer to pages C-24 to
C-25)
Parameter value
Minimum value
Maximum value
Default value
Next parameter
Previous parameter
Units (e.g., amp, Hz)
Multiplier

2

Divisor

2

Base

2

Offset

2

Link (source of the value) (0 = no link)
Always zero (0)
Parameter name

8

Get

DPI
Descriptor

BOOL[32]

Descriptor (refer to pages
C-24 to C-25

9

Get/Set DPI

Parameter
Value

Various

Parameter value in NVS

3

10

Get/Set DPI RAM

Parameter
Value

Various

Parameter value in temporary
memory

Advertising