Rockwell Automation RECOMM-ENET EtherNet/IP Communications Module User Manual

Page 46

Advertising
background image

4-20

EtherNet/IP Communications Module

Firmware 2.xxx (and earlier)

By default, the firmware 2.xxx (and earlier) module web pages are
enabled. To disable the module web pages, use Access Control (54)
to set the Web Enable Bit 0 value to “0” (Disabled). You can also
protect the configured settings for e-mail messaging using Access
Control (54). To do this, the value of E-mail Config Bit 1 must be“0”
(Disabled default). E-mail messaging will remain active regardless
of whether or not its settings are protected — unless e-mail
messaging was never configured.

Changes to this parameter take effect immediately. A reset is not
required.

Firmware 3.xxx (and later)

By default, the firmware 3.xxx (and later) module web pages are
disabled. Refer to Figure 3.1 and set the Web Pages Switch (SW2)
to the “Enabled Web” (UP) position.

Important:For a change to the switch setting to take effect, the

module must be reset.

Bit 0 of Web Features (56) is used to protect the configured settings
for e-mail notification. By default, settings are not protected and the
user can make changes. To protect an e-mail configuration, set the
value of E-mail Cfg Bit 0 to “0” (Disabled). You can unprotect the
configuration by changing Bit 0 back to “1” (enabled). E-mail
notification will always remain active regardless of whether or not its
settings are protected — unless e-mail notification was never
configured.

Bit 0 is the right-most bit. In figure 4.28 it is highlighted and equals
“1”.

Figure 4.27 – Example Web Access Control Screen on an LCD OIM

Port 5 Device

RECOMM-ENET

Parameter #: 54
Access Control
x x x x x x x x x x x x x x 0

1

Web Enable

b00

Bit

Description

0

Web Enable (Default = 1 = enabled)

1

E-mail Config (Default = 0 = disabled)

2 - 31 Not Used