C-32

EtherNet/IP Communications Module

Instance Attributes

Services

Attribute

ID

Access

Rule

Name

Data Type

Description

0

Get

Read Full

STRUCT of
STRING[16]
LWORD or
STRUCT

BOOL[16]

Name of the timer
Elapsed time in milliseconds unless
timer is a real time clock (See
attribute 2)
See Attribute 3

1

Get

Timer Text

STRING[16]

Name of the timer

2

Get/Set

Timer Value LWORD

-OR-
STRUCT of
WORD
BYTE
BYTE
BYTE
BYTE
BYTE
BYTE

Elapsed time in milliseconds unless
the timer is a real time clock.
Real Time Clock Data:
Milliseconds (0 – 999)
Seconds (0 – 59)
Minutes (0 – 59)
Hours (0 – 23)
Days (1 – 31)
Months (1 = January, 12 = December)
Years (since 1972)

3

Get

Timer
Descriptor

BOOL[16]

BOOL[0]: (0 = invalid data,

1 = valid data)

BOOL[1]: (0 = elapsed time,

1 = real time)

BOOL[2 - 15]: Not used

Service Code

Implemented for:

Service Name

Class

Instance

0x0E

Yes

Yes

Get_Attribute_Single

0x10

Yes

Yes

Set_Attribute_Single