Using I/O Messaging

6-7

6.5

Using Datalinks

A Datalink is a mechanism used by Reliance Electric drives to
transfer data to and from the controller. Datalinks allow a parameter
value to be changed without using an Explicit Message. When
enabled, each Datalink consumes either two 16-bit or 32-bit words
in both the input and output image depending on its size. The size
of Datalinks (16-bit words or 32-bit words) is determined by the
drive and displayed in Datalink Size (19) in the module.

Rules for Using Datalinks

Each set of Datalink parameters in a Reliance Electric drive can
be used by only one module. If more than one module is
connected to a single drive, multiple modules must not try to use
the same Datalink.

Parameter settings in the drive determine the data passed
through the Datalink mechanism. Refer to the documentation for
your drive.

When you use a Datalink to change a value, the value is not
written to the Non-Volatile Storage (NVS). The value is stored in
volatile memory and lost when the drive loses power. Thus, use
Datalinks when you need to change a value of a parameter
frequently.