Rockwell Automation RECOMM-ENET EtherNet/IP Communications Module User Manual

Page 31

Advertising
background image

Configuring the EtherNet/IP Module

4-5

Step 5.

Click OK to apply the settings. The module appears in the
Relation List with the new settings as shown in figure 4.5.

Step 6.

To assign this configuration to the module permanently,
click Disable BOOTP. When power is cycled on the
module, it will use the configuration you assigned it and
will not issue new BOOTP requests.

Note: To enable BOOTP for a module that has had
BOOTP disabled:

a. Select the module in the Relation List

b. Click Enable BOOTP.

c. Reset the module.

Step 7.

To save the Relation List, select File > Save.

Table 4.2 – Editing the New Entry Dialog Box

In this field:

Enter this information:

IP Address

1

1

For definitions, refer to the Glossary.

A unique IP address for the module.

Subnet Mask

1

A subnet mask for the module’s network.

Gateway

1

The IP address of the gateway device on the
module’s network.

Figure 4.5 – BOOTP Server Window with an Module in the Relation List