Rockwell Automation RECOMM-ENET EtherNet/IP Communications Module User Manual

Page 139

Advertising
background image

EtherNet I/P Objects

C-3

Instance Attributes

Services

Attribute

ID

Access

Rule

Name

Data Type

Description

1

Get

Vendor ID

UINT

5 = Reliance Electric

2

Get

Device Type

UINT

123

3

Get

Product Code

UINT

Number identifying product name and
rating

4

Get

Revision:
Major
Minor

STRUCT of
USINT
USINT

Value varies
Value varies

5

Get

Status

WORD

Bit 0 = Owned
Bit 2 = Configured
Bit 10 = Recoverable fault
Bit 11 = Unrecoverable fault

6

Get

Serial Number UDINT

Unique 32-bit number

7

Get

Product Name SHORT_

STRING

Product name and rating

Service Code

Implemented for:

Service Name

Class

Instance

0x05

Yes

Yes

Reset

0x0E

Yes

Yes

Get_Attribute_Single

0x01

Yes

Yes

Get_Attribute_All

Advertising