ADLINK AMP-208C User Manual

Page 103

Advertising
background image

Motion Control Theory

89

AMP-204C / AMP-208C

For EL signal homing mode with negative direction homing and
without EZ alignment, the control axis stops at MEL signal edge
after home movement is completed as shown in figure below.

Figure below illustrates how to set up Home mode 1 (EZ signal)
with positive direction homing and EZ alignment. After home
movement is completed the control axis stops at the edge of EZ
signal.

• Relevant axis parameters setup

Axis parameters

Axis
parameter
values

Description to axis parameter value

PRA_HOME_MODE

1

Employing home mode 1 (EZ signal) homing

PRA_HOME_DIR

0

Employing positive direction forward homing

PRA_HOME_EZA

1

Further align with signal EZ, 0: No, 1: Yes

PRA_HOME_S

0

S-curve factor

PRA_HOME_ACC

ACC

Acceleration and deceleration in unit of (distance unit of
measure/sec.

2

)

PRA_HOME_VS

VS

Initial speed in unit of (distance unit of measure/sec.)

PRA_HOME_VM

VM

Speed of original postion searching in unit of (distance
unit of measure/sec.)

PRA_HOME_VO

VO

Homing speed in unit of (distance unit of measure/sec.)

PRA_HOME_SHIFT

0

Shift amount of homing position (distance unit onf
measure)

Condition B

Initial position

Home

position

Condition A

VM: Home searching speed

VO: Home approaching speed