ADLINK AMP-208C User Manual

Page 138

Advertising
background image

Motion Control Theory

124

AMP-204C / AMP-208C

Motion status is described below in sequence of bit:

Bit0~ bit4:

CSTP (Command stop):

When this signal is ON, the controller

is not sending movement command.

VM:

when this signal is ON, the movement reached its

maximum velocity settings.

ACC:

when this signal is ON, the movement is accelerating.

DEC:

when this signal is ON, the movement is decelerating.

DIR:

when this signal is ON, the movement is moving at

positive direction. When movement stops, the DIR saves
status right before movement stopped.

15

JOG

Jog movement in progress

16

ASTP

Abnormal stop. Clear this signal after next
movement is executed

17

BLD

The axis is running blending movement

18

PRED

Pre-offset event, clear this signal after next
movement is executed

19

POSTD

Post-offset event, clear this signal after next
movement is executed

20~27

--

(Reserved)

28

GER

In geared, the axis is a slave one

29~31

--

(Reserved)

Bit No.

Define

Description

Advertising