Figure 4-1, Format of pulse signal – ADLINK AMP-208C User Manual

Page 75

Advertising
background image

Motion Control Theory

61

AMP-204C / AMP-208C

In this mode users must pay special attention to pulse signal
format acceptable to the motor to be drived. The motor works
normally only when being drived by correct pulse format signal,
otherwise the motor may fail to work in erroneous direction or with
abnormal shaking. Users must correctly set up the controller
before any motion control after the software is initialized. This
controller provides two pulse signal output format:

• OUT / DIR signal format: At this mode, the OUT signal indicates

frequency and amount of output pulses where DIR indicates
direction of machine movement.

• CW / CCW signal format: At this mode the CW/CCW signal

indicates both machine movement direction and pulse output
frequency and amount

Figure 4-1: Format of pulse signal

The signal format can be set up in axis parameters:

Param. No.

Define symbol

Description

81h (129)

PRA_PULSE_OUT_MODE

Pulse output format setup