background image

Signal Connection

51

AMP-204C/AMP-208C

3.8

SVON Output

AMP-204C / AMP-208C provides 4/8 servo-on output channels
and utilize the servo-on signal to enable servo drive for pulse or
analog commands input. If there is abnormality is encountered
during movement, the AMP-204C / AMP-208C turns off this signal
automatically and stops all motion control commands. See below
for corresponding pins of servo-on signal output on DIN-825-GP4:

• Signal connection diagram:

Figure 3-9: Servo-on signal connection example

CMAx / CMPx

Pin No (x=1~4)

Signal Name

(n=1~4)

Description

Axis #

1

SVON(n)

Servo-on output

1~4

NOTE

NOTE

AMP-208C requires two DIN-825-GP4 for eight axes motion
control functions
# 1 controls axes 1 ~ 4 and #2 controls axes 5 ~ 8