Motion Control Theory

164

AMP-204C / AMP-208C

4.10.2

Software Protection

The controller provides software protection mechanism of
software limit and postion error protection.

4.10.2.1

Soft-limit Signal

Software limit functions almost the same as that of the hardware
limit with the exception that limit signal is generated by checking
location of each axis with the software limit function. There are the
same plus limit (PEL) and minus limit (MEL) signals. Steps of
using the software limit are described below:

1. Set up position of software limit with axis parameters

PRA_SPEL_POS and PRA_SMEL_POS shown in table

below.

2. Set up stop mode in response to limit signal. You can

select decelerating stop or immediate stop with axis

parameter PRA_EL_MODE (0x02) and PRA_SD_DEC

(0x07).

3. Start up software limit function with axis partameter

PRA_SPEL_EN (0x08) and PRA_SMEL_EN (0x09)

shown in table below.

Please run homing operation to ensure limit position of the
coordiante system before the software limit function can be
started.

After the software limit function is initiated, you may use the
function library provided by the controller to display signal status.
This IO monitoing function is described below:

APS_motion_io_status ();

NO

Define

Description

02h

PRA_EL_MODE

EL signal stop mode
See deceleration rate reference parameter,
PRA_SD_DEC, for deceleration stop mode:

07h

PRA_SD_DEC

Set up rate for deceleration stop

08h

PRA_SPEL_EN

Soft PEL switch

09h

PRA_SMEL_EN

Soft MEL switch

0Ah

PRA_SPEL_POS

Soft PEL position

0Bh

PRA_SMEL_POS

Soft MEL position