48

Signal Connection

3.5

ORG Input

AMP-204C / AMP-208C provides 4/8 original position switch input
channels. Working together with the home movement described in
Section 4.3, this function returns the body to its original position
(also known as the zero position). See below for corresponding
pins of original position switch signal input on DIN-825-GP4:

• Signal connection diagram:

Figure 3-6: Original position switch signal connection example

J1/J2 Pin No

Signal Name

Description

Axis #

4

ORG(3) / ORG(1)

Original position switch input (3) / (1)

3 / 1

8

ORG(4) / ORG(2)

Original position switch input (4) / (2)

4 / 2

NOTE

NOTE

AMP-208C requires two DIN-825-GP4 for eight axes motion
control Function
# 1 controls axes 1 ~ 4 and #2 controls axes 5 ~ 8