Motion Control Theory

83

AMP-204C / AMP-208C

ORG signal of most mechanical device has two directional edges
(the two ends of signal fender). Figure above indicates that when
the homing direction parameter in axis parameters is set to
positive direction (PRA_HOME_DIR), the control axis starts
searching from positive direction (the ascending direction of
position command). And stops at the left edge of ORG signal
(close to MEL mechanical signal).

On the contrary, if the homing direction parameter in axis parameters
is set to negative direction (PRA_HOME_DIR), the control axis starts
seraching from negative direction (the descending direction of
position command). And stops at the right edge of ORG signal (close
to PEL mechanical signal). Figure below indicates home movement
when “PRA_DIR” is set to negative direction:

• Relevant axis parameters setup

Axis parameters

Axis
parameter
values

Description to axis parameter value

PRA_HOME_MODE

0

Employing home mode 0 (homing by ORG signal)

PRA_HOME_DIR

1

By negative direction forward homing

PRA_HOME_EZA

0

Further align with signal EZ, 0: No, 1: Yes

PRA_HOME_S

0

S-curve factor

PRA_HOME_ACC

ACC

Acceleration and deceleration in unit of (distance unit
of measure/sec.

2

)

PRA_HOME_VS

VS

Initial speed in unit of (distance unit of measure/sec.)

PRA_HOME_VM

VM

Speed of original postion searching in unit of (distance
unit of measure/sec.)

PRA_HOME_VO

VO

Homing speed in unit of (distance unit of
measure/sec.)

PRA_HOME_SHIFT

0

Shift amount of homing position (distance unit onf
measure / pulse)