Motion Control Theory

91

AMP-204C / AMP-208C

4.3.3

Single EZ Signal Homing

Most linear motor mechanism set up only one position mark
signal. This mode is used in the said mechanism.

Figure below illustrates how to set up Home mode 2 (single EZ
signal) with positive direction homing. After home movement is
completed the control axis stops at the edge of EZ signal.

• Relevant axis parameters setup

Axis parameters

Axis
parameter
values

Description to axis parameter value

PRA_HOME_MODE

2

Employing home mode 2 (single EZ signal) homing

PRA_HOME_DIR

0

Employing positive direction forward homing

PRA_HOME_EZA

0

Further align with signal EZ, 0: No, 1: Yes

PRA_HOME_S

0

S-curve factor

PRA_HOME_ACC

ACC

Acceleration and deceleration in unit of (distance unit
of measure/sec.

2

)

PRA_HOME_VS

VS

Initial speed in unit of (distance unit of measure/sec.)

PRA_HOME_VM

VM

Speed of original postion searching in unit of (distance
unit of measure/sec.)

PRA_HOME_VO

VO

Homing speed in unit of (distance unit of
measure/sec.)

PRA_HOME_SHIFT

0

Shift amount of homing position (distance unit onf
measure)

Advertising