56

Signal Connection

IOIF1 Pin No.

Signal Name

Description

1~8

DI(1)~(8)

General purpose IOIF2 digital input signal (1)~(8)

IOIF2 Pin No.

Signal Name

Description

1~8

DI(9)~(16)

General purpose digital input signal (9)~(16)

IOIF3 Pin No.

Signal Name

Description

Axis #

1~5

DO(1)~(5)

General purpose digital output signal

(1)~(5)

-

NOTE

NOTE

The digital output current may reach 250mA

IOIF3 Pin No.

Signal Name

Description

Axis #

6~8

DO(6)~(8)

General purpose digital output signal

(6)~(8)

-

IOIF4 Pin No.

Signal Name

Description

Axis #

1~8

DO(9)~(16)

General purpose digital output signal

(9)~(16)

-

NOTE

NOTE

1. Please connect DICOM to external power supply

(24VDC in general) if possible.

2. Please connect DOCOM to ground (GND) of

external power supply if possible.

Advertising