3 home move, Home move – ADLINK AMP-208C User Manual

Page 92

Advertising
background image

Motion Control Theory

78

AMP-204C / AMP-208C

4.3

Home Move

After power on and before executing any motion control, a motion

control system executes home movement to set up the zero

position of the coordinate system.
Commonly available stepper motor, servo drive or linear motor

mechanism accompanied by optical scale employs incremental

type encoder which requires some mechanical signal to set up the

original position during home operation. These mechanical signals

are ORG, EZ, PEL, and MEL. Some servo drives are featured with

absolute type encoder, e.g. J3-B type (SSCNET 3) of Mitsubishi,

that require at least one home movement after system

initialization. No more homing operation is required after the

absolute coordinate system is established.
After the homing command is received, the controller starts

searching for original position / zero position with the help of some

external signals. After the home movement is completed the

controller axis stops at the original postion while command

position and feedback position reset to zero. All the home

movement related operations are executed by the controller

automatically. No user interaction is required. Just wait it to

complete automatically.
You can finish home movement operation by steps described

below:

• Set up home mode and relevant parameters
• Start up home move
• Wait for home move to complete. (You may check the status by

polling or interrupt.)

• If home move does not complete successfully you may

troubleshooting by steps described below

Relevant APS API described below:

I32 APS_motion_status (I32 Axis_ID);
Relevant axis parameters:

Param. No.

Define symbol

Description

10h (16)

PRA_HOME_MODE

Home mode settings

11h (17)

PRA_HOME_DIR

Homing direction settings

12h (18)

PRA_HOME_CURVE

Home move S-factor

13h (19)

PRA_HOME_ACC

Homing acceleration/deceleration settings

15h (21)

PRA_HOME_VM

Homing maximum velocity

17h (23)

PRA_HOME_SHIFT

Home position and shift distance of positioning
signal

Advertising