Figure 4-50, Relation of blending (bld) signal vs motion – ADLINK AMP-208C User Manual

Page 144

Advertising
background image

Motion Control Theory

130

AMP-204C / AMP-208C

Bit 17: Blending movement - BLD

Continuous interpolation has several speed succession method.
The blending method has a transition region at the interconnection
points of two paths (as shown in figure below). The BLD signal
indicate that the axis is entering this area.

Figure 4-50: Relation of blending (BLD) signal VS motion

Bit 18 and 19: Pre- and post distance event

Every position movement command can set up pre-distance and
post-distance to trigger the controller to issue signals when
distance of movement meet given conditions.

The controller starts recording shift distance of movement when
point to point movement is started. When distance of movement is
greater than pre-distance, the pre-distance event occurs.
Similarly, when remining shift distance of the point to point
movement is less than the post-distance, then post-distance event
occurs. Relation between movement and signal shown in figure
below:

Start deceleration

V

I

II

Blending

T

Time

BLD

Transition

area

E1

S1

E2

Advertising