J5 • j6 • ioif1, 32 getting start with the installation – ADLINK AMP-208C User Manual

Page 46

Advertising
background image

32

Getting Start with The Installation

• J5

• J6

• IOIF1:

No.

Name

I/O

Function of Axis

No.

Name

I/O

Function of Axis

1

I24V

--

Ext. power supply, +24V

4

DOCOM

--

Digital output common

2

IGND

--

Ext. power ground

5

EEMG

|

Ext. Emergency signal

3

DICOM

--

Digital input common

6

--

--

--

NOTE

NOTE

1. Please connect DICOM to external power supply

(24VDC in general) if possible.

2. Please connect DOCOM to ground (GND) of

external power supply if possible.

No.

Name

I/O

Function of Axis

No.

Name

I/O

Function of Axis

1

EDO1

c

Digital output, (1)

4

EDO4

c

Digital output, (4)

2

EDO2

c

Digital output, (2)

5

DOCOM

c

Digital output common

3

EDO3

c

Digital output, (3)

6

--

c

--

No.

Name

I/O

Function of Axis

No.

Name

I/O

Function of Axis

1

DI1

I

Additional isolated digital
input, (1)

6

DI6

I

Additional isolated digital
input, (6)

2

DI2

I

Additional isolated digital
input, (2)

7

DI7

I

Additional isolated digital
input, (7)

3

DI3

I

Additional isolated digital
input, (3)

8

DI8

I

Additional isolated digital
input, (8)

4

DI4

I

Additional isolated digital
input, (4)

9

DICOM

--

Digital input common

5

DI5

I

Additional isolated digital
input, (5)

--

--

--

--

Advertising