ADLINK AMP-208C User Manual

Page 171

Advertising
background image

Motion Control Theory

157

AMP-204C / AMP-208C

b. Instruction command setup

The instruction command is executed simultaneously with the
point table's movement one. That is, it may control digital outputs
concurrently at different movement section during motion
execution.

c. Set movement command to point table

The point table offers movement commands of straight line, arc
and spiral interpolation which can set movement commands in
point table with the paired APS function.

Movement parameter setup Paired APS function

Absolute / relative movement APS_pt_set_absolute / APS_pt_set_relative

Maximum speed

APS_pt_set_vm

Ending speed

APS_pt_set_ve

Acceleration

APS_pt_set_acc

Deceleration

APS_pt_set_dec

Acceleration and
deceleration

APS_pt_set_acc_dec

S-factor

APS_pt_set_s

Speed blending between
adjacent paths
Please refer to Section 4.7.3.

APS_pt_set_trans_buffered (buffer)
APS_pt_set_trans_inp (buffered in-place)
APS_pt_set_trans_blend_dec (blend - deceleration)
APS_pt_set_trans_blend_dist (blend - residue-distance)
APS_pt_set_trans_blend_pcnt (blend - residue-distance ratio)

Instruction command (executed
along with the movement
command)

Paired APS function

Digital output (DO)

APS_pt_ext_set_do_ch

VAO table switch

APS_pt_ext_set_table_no

Movement
commands

Paired APS function

Straight line
interpolation

APS_pt_line

Arc interpolation

APS_pt_arc2_ca / APS_pt_arc2_ce
APS_pt_arc2_ca / APS_pt_arc2_ce

Spiral interpolation

APS_pt_sprial_ca / APS_pt_sprial_ce

Dwell

APS_pt_dwell

Advertising