5 jog move, Jog move, Figure 4-17 – ADLINK AMP-208C User Manual

Page 111

Advertising
background image

Motion Control Theory

97

AMP-204C / AMP-208C

4.5

Jog Move

Jog operation is commonly available at control panel of machine.
Its main function is to manually control the movement of motion
axis or fucntion together with mechanical switch with digital input
to use DI signal as the jog movement startup signal. You may use
switch on control panel to operate jog movement by setting up
relevant parameters instead of coding control program.

There are two jog movement modes:

1. Continuous mode: This is similar to velocity movement

with given maximum speed and acceleration profile.

When JOG-ON signal (*) produces rising edge event

trigger then the specified control axis starts velocity

movement. When JOG-ON signal (*) produces falling

edge event trigger then the specified control axis starts

deceleration stop. See figure below:

Figure 4-17: Relation between V-T chart of JOG movement and JOG-ON

signal

NOTE

NOTE

JOG-ON signal is a software digital signal where ON is repre-
sented by value 1 and OFF by 0

ON(1)

OFF(0)

JOG-ON

V

T

Signal