ADLINK AMP-208C User Manual

Page 109

Advertising
background image

Motion Control Theory

95

AMP-204C / AMP-208C

• Example 1:

Set up parameters and start up velocity movement. See below
for example process:

1. Change maximum speed after 2 seconds
2. Change maximum speed after 2 seconds
3. Stop by deceleration after 2 seconds

#include

"APS168.h"

#include

"APS_define.h"

#include

"ErrorCodeDef.h"

void

velocity_move_example()

{

I32 axis_id =

0

;

F64 speed_1 =

500.0

;

F64 speed_2 =

1000.0

;

F64 speed_3 =

600.0

;

APS_set_axis_param_f( axis_id, PRA_STP_DEC,

10000.0

);

APS_set_axis_param_f( axis_id, PRA_CURVE,

0.5

);

//Set acceleration rate

APS_set_axis_param_f( axis_id, PRA_ACC,

10000.0

);

//Set acceleration rate

APS_set_axis_param_f( axis_id, PRA_DEC,

10000.0

);

//Set deceleration rate

APS_vel( axis_id,

0

, speed_1,

0

);

// Start a velocity move

Sleep(

2000

);

// Wait 2 second

APS_vel( axis_id,

0

, speed_2,

0

);

// Change speed on the fly

Sleep(

2000

);

// Wait 2 second

APS_vel( axis_id,

0

, speed_3,

0

);

// Change speed on the fly

Sleep(

2000

);

// Wait 2 second

APS_stop_move( axis_id );

// Stop

}

Advertising