Figure 4-44, Relation of different motion signals vs motions – ADLINK AMP-208C User Manual

Page 139

Advertising
background image

Motion Control Theory

125

AMP-204C / AMP-208C

Relation between movement and signal shown in figure below:

Figure 4-44: Relation of different motion signals VS motions

Bit 5: Motion Done – MDN

Single movement command or multiple movement command is
completed. Single movement command is a single axis point to
point movement and multiple axes point to point movement.
Multiple movement is like homing movement combinated by a
series of movement. With this signal you may use polling or
interrupt event generation to schedule movement process.

Note: Abnormal movement stop will generate this signal as well.
You may ensure abnaormal movement stop by checking ASTP
signal.

Time

Velocity

Time

MV

ACC

DEC

DIR

CSTP

Advertising
This manual is related to the following products: