Motion Control Theory

142

AMP-204C / AMP-208C

b. Mode 2: PWM frequency mode with fixed width

This control mode changes PWM frequency according to speed at
fixed PWM pulse width. Under fixed PWM pulse width W, the VAO
table gives PWM frequency 1/T

1

, 1/T

2

and 1/T

3

at speed V

1

, V

2

and V

3

as shown in figure below. To use this mode to

1. Set up control mode: Use APS_set_vao_param( ) to set

up value of VAO_TABLE_OUTPUT_TYPE parameter to

0x2.

2. Set up fixed PWM output pulse width: Use

APS_set_vao_param ( ) to set up parameter

VAO_TABLE_PWM_Config in unit of ns. Valid input

range is 20ns ~ 335544320 ns.

Advertising