background image

Motion Control Theory

127

AMP-204C / AMP-208C

Figure 4-46: Relation of motion done (MDN), In-homing (HMV) signals VS

motion

Bit10: Wait Move Trigger – WAIT

This signal is set ON when the signal is at status ready for movement
triggering. When trigger is sent: Use move_trigger() function to trigger
standby axis.

When parameter Flag is set to MF_WAIT (0x00100) for motion
control functions listed below, the relevant commands are set to
trigger initiated. The target axis do not start up immediately, only
the WAIT signal is set to ON.

Time

Velocity

Time

MDN

home()

HMV