Figure 4-15, Home mode 2 (case: ez) – ADLINK AMP-208C User Manual

Page 106

Advertising
background image

Motion Control Theory

92

AMP-204C / AMP-208C

Figure 4-15: Home mode 2 (Case: EZ)

Figure below set up "Home mode 2 (single EZ signal)" with
negative direction homing. After home movement is completed the
control axis stops at the edge of EZ signal.

• Relevant axis parameters setup

Axis parameters

Axis
parameter
values

Description to axis parameter value

PRA_HOME_MODE

2

Employing home mode 2 (single EZ signal) homing

PRA_HOME_DIR

1

By negative direction forward homing

PRA_HOME_EZA

0

Further align with signal EZ, 0: No, 1: Yes

PRA_HOME_S

0

S-curve factor

PRA_HOME_ACC

ACC

Acceleration and deceleration in unit of (distance unit of
measure/sec.

2

)

PRA_HOME_VS

VS

Initial speed in unit of (distance unit of measure/sec.)

PRA_HOME_VM

VM

Speed of original postion searching in unit of (distance
unit of measure/sec.)

PRA_HOME_VO

VO

Homing speed in unit of (distance unit of measure/sec.)

PRA_HOME_SHIFT

0

Shift amount of homing position (distance unit onf
measure)

Condition B

Initial position

Home position

Condition A

VM: Home searching speed

VO: Home approaching speed

Home

position

Advertising