Figure 4-52, Adjust electronic gear's auto engagement speed, 2 gantry mode – ADLINK AMP-208C User Manual

Page 147

Advertising
background image

Motion Control Theory

133

AMP-204C / AMP-208C

Figure 4-52: Adjust electronic gear's auto engagement speed

There are several conditions that may relieve gear relations in
standard mode:

1. Relieve gear relation by APS_start_gear () manually
2. If the EMG / ALM / PEL / MEL / ALM signal of slave axis

turns ON, the master axis is not affected if it is moving.

3. When slave axis received stop (), emg_stop (), and

servo_off () commands

4.9.1.2

Gantry Mode

The dual drives gantry mechanism features the following:

1. Gear relation remains unless manually relieved by

users.

2. Master axis stops when EMG / ALM / PEL / MEL / ALM

signal of slave axis is set to ON.

3. Master and slave axes stop when stop (), emg_stop (),

and servo_off () commands received by the slave axis.

4. Gear ration is fixed at 1:1 and cannot be changed.
5. Settings of engage rate are ignored.

In addition, this mode features a protection mechanism against
two levels of mis-position errors. The controller checks position
errors of both axes at every movement cycle for exceeding error
setup. If error value is greater than position error settings of level
1, it starts the deceleration stop. If error value is greater than the
level 2 position error settings the controller executes Servo-Off
operation to both axes.

Change gear ratio to ratio-3

Change gear ratio to ratio-2

Time

Start gearing A

Ratio

Ratio 2

Ratio 1

Ratio 3

Advertising