background image

Motion Control Theory

102

AMP-204C / AMP-208C

Relevant APS API described below:

I32 APS_ptp ();

// PTP move

I32 APS_ptp_v ();

// PTP move with maximum speed parameter

I32 APS_ptp_all ();

// PTP move with all speed parameter

I32 APS_relative_move ();

// Relative PTP move in I32 data

format

I32 APS_absolute_move ();

// Absolute PTP move in I32 data

format

I32 APS_stop_move ();

// deceleration stop

I32 APS_emg_stop ();

// immediately stop

• Relevant axis parameters

4.6.2

Synchronous Start

Synchronous start: This movement can set to be enabled by
trigger. When proper command is received, the axis enters a
waiting-for-trigger-signal status and starts moving after the trigger
is received. When multiple axes are in waiting-for-trigger-signal
status you may send trigger at the same time for synchronized
enabling. Please note that movement of each axis is independent
from each other and so the end time varies with offset and
acceleration profile.

Param. No.

Define symbol

Description

07h (7)

PRA_SD_DEC

stop_move (), deceleration rate

20h (32)

PRA_SF

S-factor

21h (33)

PRA_ACC

Acceleration rate

22h (34)

PRA_DEC

Deceleration rate

23h (35)

PRA_VS

Start velocity

24h (36)

PRA_VM

Maximum velocity

25h (37)

PRA_VE

End velocity

Advertising