Yaskawa GPD503 Drive User Manual

Page 105

Advertising
background image

OPERATING

OPERATION AT

PROCEDURE

DIGITAL OPERATOR

DIGITAL DISPLAY

DESCRIPTION

Frequency

EXAMPLE: Set frequency

Setting

command to 15 Hz:

(Continued)

Move to the setting digit by
using > and make the
setting with ^ and v .

Store the frequency command

Initial setting becomes frequency

value with DATA/ENTR key.

command.

(This data is stored even when
the power is off).

Press DSPL key once to
change display to monitor
output frequency.

Select

Select the rotation of motor

GPD 503 is set for forward motor

Forward

with FWD/REV key.

operation, but is still in "stopped"

Operation

(Red FWD lamp lights).

condition.

Run

Press RUN key.

GPD 503 output and motor speed

(Red lamp lights. Red lamp

increase smoothly at preset

at STOP key goes off).

acceleration rate, then hold
steady at 15 Hz.

Select

Press FWD/REV key.

GPD 503 output (and motor speed)

Reverse

(Red FWD lamp goes off,

decreases smoothly, at preset

Operation

and red REV lamp lights).

deceleration rate, to zero.

Then motor begins rotation in
reverse direction, accelerating
smoothly, then holds steady
at 15 Hz.

Change

Press DSPL key repeatedly

Motor continues running at 15 Hz.

Frequency

until frequency command

Setpoint

is again displayed.

EXAMPLE: Set 50 Hz as new

value of frequency command.

Change the frequency set

Motor continues running at 15 Hz.

point by using > , ^ and v .

(Procedure continued on next page)

Table 4-1. Test Run With Digital Operator - Continued

OPERATING

OPERATION AT

PROCEDURE

DIGITAL OPERATOR

DIGITAL DISPLAY

DESCRIPTION

1 5. 0

0. 0

– 1 5. 0

Value

decreasing

Value

increasing

F 0 1 5. 0

F 0 5 5. 0

F 0 5 0. 0

(–) is shown during

reverse operation

4-3

Value

increasing

(Display of current value

of output frequency)

F 0 1 0. 0

F 0 1 5. 0

F 0 1 5. 0

0. 0

0. 0

0. 0

1 5. 0

Advertising