33 v/f pattern - custom – Yaskawa GPD503 Drive User Manual

Page 87

Advertising
background image

2.33 V/f PATTERN - CUSTOM

A.

Cn-01: Output Voltage Regulator

Factory Setting:

230 / 460 / 575

V

Range: 0.0 to 255.0 (230V)

0.0 to 510.0 (460V)
0.0 to 733.1 (575V)

This constant sets the output voltage to be regulated. If Sn-02 is set to a value in the
range

00

to

0E

, then changing Cn-01 will automatically effect the voltage constants

(Cn-03, Cn-06 and Cn-08; see section B of this feature description) proportionally. If
Sn-02 is

0F

, then Cn-01 has no effect on the voltage constants, and the output voltage

would be determined by the voltages programmed into Cn-03, Cn-06 and Cn-08.

NOTE: Before changing Cn-01, refer to the examples below.

EXAMPLES

:

230V Drive

V

IN

V

OUT

Cn-01

230

230

230

Factory Setting

230

208

208

208

208

208

460V Drive

V

IN

V

OUT

Cn-01

460

460

460

Factory Setting

460

400

400

380

380

380

460

380

460

*

* For this condition, Custom V/Hz Pattern should be used (Sn-02 =

0F

), and Cn-01 set to Input Voltage.

For 460V units only:

• If Cn-01

*

400, then overvoltage trip point = 800 Vdc

• If Cn-01



400, then overvoltage trip point = 700 Vdc.

575V Drive

V

IN

V

OUT

Cn-01

575

575

575

Factory Setting

500

500

500

575

500

575

*

* For this condition, Custom V/Hz Pattern should be used (Sn-02 =

0F

), and Cn-01 set to Input Voltage.

For 575V units only:

• If Cn-01

*

500, then overvoltage trip point = 1040 Vdc

• If Cn-01



500, then overvoltage trip point = 910 Vdc.

2-48