Yaskawa GPD503 Drive User Manual

Page 121

Advertising
background image

TROUBLESHOOTING CHART 7.7

UNDERVOLTAGE (

Uu

) FAULT INDICATION

IS INPUT AC

SUPPLY

CORRECT?

NO

NO

YES

YES

NO

YES

IS THERE

AT LEAST 450VDC

(FOR 460V GPD 503) OR

225VDC (FOR 230V GPD 503)

FROM TERMINAL B1 TO

B2 (OR B0 TO B1)?

- INCREASE VOLTAGE

WITHIN PROPER RANGE.

- CHECK WIRING BETWEEN

MAIN AC CONTACTOR
AND GPD 503.

GPD 503
IS FAULTY.

REMOVE NOISE SOURCE:

• CONNECT SURGE
SUPPRESSOR TO RELAY
AND MAGNETIC CON-
TACTOR COILS.

• PROVIDE LINE FILTER
TO REMOVE NOISE ON
INPUT POWER LINE.

ERRONEOUS OPERATION

DUE TO NOISE?

CONTROL PCB OR BASE
DRIVE PCB IS FAULTY.
REPLACE FAULTY BOARD.

7-9

Advertising