2.30 THERMAL MOTOR OVERLOAD PROTECTION

Continued

2-46.1

0

50

100

150

200

200

100

50

20

10

5

2

TIME (MIN.)

40 Hz

60 Hz

40 Hz

60 Hz

IM
IM100

(%)

Sn-14 = 0000 Upper Curve
Sn-14 = 0100 Lower Curve

IM = ACTUAL MOTOR CURRENT
IM100 = MOTOR BASE CURRENT (Cn-09)

20 Hz

10 Hz

0 Hz

10 Hz

0 Hz

20 Hz

Electronic Motor Thermal

Protection Characteristics
For Variable Torque Motor

0

50

100

150

200

200

100

50

20

10

5

2

TIME (MIN.)

IM
IM100

(%)

Sn-14 = 0010 Upper Curve
Sn-14 = 0110 Lower Curve

0 Hz

5.6-60 Hz

0 Hz

5.6-60 Hz

IM = ACTUAL MOTOR CURRENT
IM100 = MOTOR BASE CURRENT (Cn-09)

Electronic Motor Thermal

Protection Characteristics

For Constant Torque Motor