A1-6 – Yaskawa GPD503 Drive User Manual

Page 130

Advertising
background image

CONSTANT

SET

FACTORY

USER

PARA.

NUMBER

DATA NAME

DIGIT

DATA

FUNCTION

SETTING

SETTING

REF.

Sn-11 Protective

XXXX

0

Braking resistor (heat sink

0000

Separate

Character-

mounted) not provided.

Option

istics

Overheat protection disabled.

Instruction

Select 2

Sheet

(Momentary

1

Braking resistor (heat sink

Power Loss

mounted) provided. Over-

Protection)

heat protection enabled.

XXXX

0

Fault contact status during

2.5B

auto restart: remains open

1

Fault contact status during
auto restart: closes

XXXX

0

Operation stops when momen-

2.16, 2.5A

tary power loss is detected

1

Operation continues during
momentary power loss

XXXX

Not used

– –

Sn-12 Protective

XXXX

0

External fault signal:

0100

2.12A

Character-

N.O. contact input

istics
Select 3

1

External fault signal:

(External

N.C. contact input

Fault Signal

XXXX

0

External fault signal

Input at

always detected

Terminal 3)

1

External fault signal only
detected during operation

XXXX

Condition when external fault
signal is detected:

00 = Ramp to stop (major failure)
01 = Coast to stop (major failure)
10 = Emergency stop (major

failure)

Time to stop
determined by
bn-04 set value

11 = Continue operation

(minor failure)

Table A1-3. System Constants (Sn-XX) - Continued

CONSTANT

SET

FACTORY USER

PARA.

NUMBER DATA NAME DIGIT DATA

FUNCTION

SETTING SETTING

REF.