2.24 REMOTE/LOCAL AND REFERENCE SELECTION Continued

Mode 3 (An-01, Manual, An-03 thru An-09) uses An-01, Manual and An-03 thru

An-09.

The input commands at terminals 5 thru 8 are
binary coded to select the appropriate reference
command, where An-01 is selected by binary zero
and An-09 (Jog) is selected by binary 8. For
example, if the value in An-04 is the desired
frequency reference, enter 0011 at terminals 5
thru 8. As a standard, the right-most bit and
terminal 5 are the LSB.

Sn-04 = local operation.
Sn-15 = frequency reference select 1 at

terminal 5 (Auto/Manual).

Sn-16 = frequency reference select 2 at

terminal 6.

Sn 17 = frequency reference select 3 at

terminal 7.

Sn-18 = JOG reference select at terminal 8.
Sn-19 = manual reference at terminal 16.

2-WIRE CONTROL

3-WIRE CONTROL

Sn-04 = X X X

1

Sn-04 = X X X

1

Sn-15 =

03

Sn-15 =

00

Sn-16 =

04

Sn-16 =

03

Sn-17 =

05

Sn-17 =

04

Sn-18 =

06

Sn-18 =

06

Sn-19 =

00

Sn-19 =

00

GPD 503

5 (Sn-15)

6 (Sn-16)

7 (Sn-17)

8 (Sn-18)

F000.0

Freq.

External Terminal

Ref.

8

7

6

5

An-01

0

0

0

Manual

0

0

1

(Multi-func.)

An-03

0

1

0

An-04

0

1

1

An-09

1

X

X

Freq.

External Terminal

Ref.

8

7

6

5

Freq.

External Terminal

Ref.

8

7

6

5

An-01

0

0

0

0

Manual

0

0

0

1

(Multi-func.)

An-03

0

0

1

0

An-04

0

0

1

1

An-05

0

1

0

0

An-06

0

1

0

1

An-07

0

1

1

0

An-08

0

1

1

1

An-09

1

X

X

X

Freq.

External Terminal

Ref.

8

7

6

5

1 = Closed; 0 = Open;
X = No effect;

= FWD/REV

2-37