Appendix 7. dynamic braking connections, A7-1 – Yaskawa GPD503 Drive User Manual

Page 150

Advertising
background image

Appendix 7. DYNAMIC BRAKING CONNECTIONS

GENERAL.

Dynamic braking (DB) enables the motor to be brought to a smooth and rapid

stop. This is achieved by dissipating the regenerative energy of the AC motor across the
resistive components of the Dynamic Braking option. For further details on dynamic
braking operation, see the instruction sheet shipped with dynamic braking components.

The GPD 503 in 230V 1-10HP (CT), 460V 1-20HP (CT), or 575V 5-25HP (CT) range has an
integral braking transistor; all higher rated drives require the use of external Braking
Units (also referred to as Braking Modules) which provide the braking transistor circuitry.
In addition, to make use of the Dynamic Braking function requires adding a heat sink
mount Braking Resistor (for 3% duty cycle; only available for the 230 1-5HP (CT) or 460V
1-3HP (CT) range) or external Braking Resistor Units (for 10% duty cycle).

Since the 3% Braking Resistor mounts directly to the drive’s heat sink, any braking
resistor overheating is sensed as a drive heatsink overtemperature fault. But for Braking
Resistor Units, interconnection to external control circuitry is necessary to ensure that
braking resistor overheating is communicated to the drive as a fault condition.

Available MagneTek dynamic braking components for 230V and 460V units are listed in
Table A7-1. To select dynamic braking components for 575V units, refer to Table A7-2.

A7-1

DRIVE

BRAKING MODULE

HS RESISTOR

(1)

BRAKING UNIT

DRIVE

BRAKING MODULE

HS RESISTOR

(1)

BRAKING UNIT

HP (CT)

PART NO. QTY Reqd

PART NO.

PART NO.

QTY Reqd HP (CT)

PART NO. QTY Reqd

PART NO.

PART NO.

QTY Reqd

1

N/A

50185430

50185130

1

1

N/A

50185530

50185330

1

2

50185431

50185131

1

2

50185531

50185331

1

3

50185432

50185132

1

3

50185532

50185332

1

5

50185433

50185133

1

5

N/A

50185333

1

7.5

N/A

50185134

1

7.5

50185334

1

10

50185135

1

10

50185335

1

15

50185034

1

51085136

1

15

50185336

1

20

50185034

1

50185137

1

20

50185337

1

25

50185035

1

50185138

1

25

50185234

1

50185338

1

30

50185035

1

50185139

1

30

50185234

1

50185339

1

40

50185034

2

50185137

2

40

50185234

1

50185340

1

50

50185034

2

50185137

2

50

50185235

1

50185341

1

60

50185035

2

50185139

2

60

50185235

1

50185342

1

75

50185035

2

50185139

2

75

50185234

2

50185340

2

100

50185035

3

50185139

3

100

50185235

2

50185342

2

150

50185234

3

50185340

3

200

50185235

4

50185342

4

250

50185235

5

50185342

5

300

50185235

5

50185342

5

400

50185235

6

50185342

6

For 230V GPD 503s

For 460V GPD 503s

Table A7-1. GPD 503 DB Components

(1)

When the heat sink mount Braking Resistor is used, DO NOT wire a Braking Unit to the drive.

Advertising