Control constants (cn-xx), A1-11 – Yaskawa GPD503 Drive User Manual

Page 135

Advertising
background image

CONSTANT

INCRE- SETTING

FACTORY

USER

PARA.

NUMBER

DATA NAME

MENT

RANGE

SETTING SETTING

REF.

Cn-01

Output Voltage Regulator

0.1 V

0.0 - 255.0

230.0

2.32

(230V)

(230V)

0.0 - 510.0

460.0

(460V)

(460V)

0.0 - 730.0

575.0

(575V)

(575V)

Cn-02

Frequency - Max.

0.1 Hz

50.0 - 400.0

60.0

2.32

See Note 1

Cn-03

Voltage - Max.

0.1 V

0.0 - 255.0

230.0

2.31

(230V)

(230V)

0.0 - 510.0

460.0

(460V)

(460V)

0.0 - 730.0

575.0

(575V)

(575V)

See Note 1

Cn-04

Frequency - Max. Voltage Point

0.1 Hz

0.0 - 400.0

60.0

2.31

See Note 1

Cn-05

Frequency - Midpoint

0.1 Hz

0.0 - 400.0

3.0

2.31

See Note 1

Cn-06

Voltage - Midpoint

0.1 V

0.0 - 255.0

17.2

2.31

(230V)

(230V)

0.0 - 510.0

34.4

(460V)

(460V)

0.0 - 730.0

575.0

(575V)

(575V)

See Note 1

Cn-07

Frequency - Min.

0.1 Hz

0.0 - 400.0

1.5

2.31

See Note 1

Cn-08

Voltage - Min.

0.1 V

0.0 - 255.0

11.5

2.31

(230V)

(230V)

0.0 - 510.0

23

(460V)

(460V)

0.0 - 730.0

575.0

(575V)

(575V)

See Note 1

Cn-09

Motor Rated Current

0.1 A

(10% - 200% of

See App. 3,

2.35

inverter rated

Table A3-1

current)

See Note 3

Cn-10

DC Injection Braking Start Freq. 0.1 Hz

0.0 - 10.0

1.5

2.8B, 2.8D

See Note 1

Cn-11

DC Injection Braking Current

1 %

0 - 100

50

2.8B, 2.8C

See Note 4

Cn-12

DC Injection Time at Stop

0.1 s

0.0 - 25.5

0.0

2.8A, 2.8B

Cn-13

DC Injection Time at Start

0.1 s

0.0 - 25.5

0.0

2.8B

Table A1-4. Control Constants (Cn-XX)

CONSTANT

INCRE- SETTING

FACTORY

USER

PARA.

NUMBER

DATA NAME

MENT

RANGE

SETTING SETTING

REF.

A1-11