CONSTANT

INCRE- SETTING

FACTORY

USER

PARA.

NUMBER

DATA NAME

MENT

RANGE

SETTING SETTING

REF.

Cn-14

Frequency Command

1 %

0 - 109

100

2.14

Upper Limit

Cn-15

Frequency Command

1 %

0 - 109

0

2.14

Lower Limit

Cn-16

Prohibit Frequency 1

0.1 Hz

0.0 - 400.0

0.0

2.7A

Cn-17

Prohibit Frequency 2

0.1 Hz

0.0 - 400.0

0.0

2.7A

Cn-18

Prohibit Frequency 3

0.1 Hz

0.0 - 400.0

0.0

2.7A

Cn-19

Prohibit Frequency Deadband

0.1 Hz

0.0 - 25.5

1.0

2.7B

Cn-20

Operator Display Mode

1

0 - 39999

0

2.9

Reference and Indication

Cn-21

Speed Coincidence Frequency

0.1 Hz

0.0 - 400.0

0.0

2.23, 2.21

Cn-22

Speed Coincidence Bandwidth

0.1 Hz

0.0 - 25.5

2.0

2.23, 2.21

Cn-23

Carrier Frequency Upper Limit

0.1 kHz

0.4 - 15.0

See Note 3

2.36

Cn-24

Carrier Frequency Lower Limit

0.1 kHz

0.4 - 15.0

See Note 3

2.36

Cn-25

Frequency Proportion Gain

1

0 - 99

0

2.36

Cn-26

Overtorque Detection Level

1 %

30 - 200

160

2.18, 2.22

Cn-27

Overtorque Detection Time

0.1 s

0.0 - 25.5

0.1

2.22

Cn-28

Stall Prevention Level During

1 %

30 - 200

170

2.29

Accel (Constant Torque Region)

Cn-29

Stall Prevention Limit During

1 %

30 - 200

50

2.29

Accel (Constant HP Region)

Cn-30

Stall Prevention Level at Set

1 %

30 - 200

160

2.29

Frequency

Cn-31

Motor-to-Motor Cable

0.001

1 0.000 - 65.535

See Note 3

– –

Resistance

Cn-32

Torque Compensation Iron

1 W

0 - 65535

See Note 3

– –

Loss

Cn-33

Torque Compensation Limiter

1 V

0 - 50

(230V)

See Note 3

– –

0 - 100

(460V)

Cn-34

Motor No-load Current

1 %

0 - 99

30

2.35

See Note 2

Cn-35

Slip Compensation Primary

0.1 s

0.0 - 25.5

2.0

2.35

Delay Time

Cn-36

No. of Auto-Restart Attempts

1

0 - 10

0

2.5A

Table A1-4. Control Constants (Cn-XX) - Continued

CONSTANT

INCRE- SETTING

FACTORY

USER

PARA.

NUMBER

DATA NAME

MENT

RANGE

SETTING SETTING

REF.

A1-12