Yaskawa GPD503 Drive User Manual

Page 115

Advertising
background image

TROUBLESHOOTING CHART 7.1 (Continued)

A

FROM
PRECEDING
PAGE

PROPER FREQUENCY

REFERENCE INPUT?

(TERMINAL 17(-) TO 13,

14 OR 16)

NO

NO

NO

NO

NO

CHECK EXTERNAL
CIRCUITS FOR
PROBLEM AND
REPAIR.

YES

VOLTAGE PRESENT ACROSS

OUTPUT TERMINALS

T1 (U), T2 (V) AND T3 (W)?

VOLTAGE PRESENT AT

MOTOR TERMINALS

T1 (U), T2 (V) AND T3 (W)?

VOLTAGE BALANCED

(WITHIN 2%)

BETWEEN PHASES, AT

T1 (U), T2 (V) AND T3 (W)?

GPD 503
IS FAULTY.

YES

YES

YES

YES

CHECK WIRING
BETWEEN
GPD 503
AND MOTOR.

GPD 503
IS FAULTY.

LOAD TORQUE

TOO LARGE?

- WITH GPD 503 IN

STOPPED CONDITION,
SELECT INCREASED
V/F BY REPROGRAM-
MING Sn-02.

- REDUCE LOAD

TORQUE (DISCON-
NECT LOAD).

- REPLACE GPD 503

WITH ONE OF LARGER
CAPACITY.

MOTOR

IS FAULTY.

7-3

Advertising