1-2.4

SECTION A. 230V

TERMINAL

FUNCTION

1 HP

3 TO 40 HP

L1 (R)

Three phase Main circuit input power supply

L2 (S)

200 / 208 / 220V at 50 Hz; 200 / 208 / 220 / 230V at 60 Hz

L3 (T)

T1 (U)

Three phase AC output to motor

T2 (V)

0V to max. input voltage level

T3 (W)

l

1 (r)

Power for heat sink fan

l

2 (

s

)

– – – – – –

200-230 Vac, single phase – two lines from input power

B0/–

– – – – – –

DB Unit terminals *

B1/+

DB Unit terminals (B1/+ & B2) *

DC bus terminals

– – – – – –

B2

– [ – (N) ]** DC bus terminals (B1/+ & –)

– – – – – –

+3 (P3)

DB Unit terminals (+1 & –)

+1 (P1)

[ (+3 & –) ]**

– – – – – –

DC bus terminals (+1 & –)

[ (+3 & – ) ]**

x

Power supply output for

y

– – – – – –

options (220 Vac, 30 VA)

G (E)

Ground terminal (100 ohms or less)

SECTION B. 460V

TERMINAL

FUNCTION

1 TO 60 HP

L1 (R)

Three phase Main circuit input power supply

L2 (S)

380 / 400 / 415 / 460V at 50/60 Hz

L3 (T)

T1 (U)

Three phase AC output to motor

T2 (V)

0V to max. input voltage level

T3 (W)

l

2 (

s

)

Power for heat sink fan

– – – – –

l

1 (r)

– – – – –

230 Vac single phase

Power for heat sink fan:

l

2 200 (

s

200)

l

1 to

l

2 200: 230 Vac

l

2 400 (

s

400)

– – – – –

l

1 to

l

2 400: 460 Vac

B0/–

– – – – –

DB Unit Terminals *

B1/+

DB Unit terminals

DB Unit terminals

DC bus terminals

– – – – –

B2

(B1/+ & B2) *

(B1/+ & B2)

– [ – (N) ]**

DC bus terminals

DC bus terminals

– – – – –

DB Unit Terminals

(B1/+ & –)

(B1/+ & B0/–)

(+1 & –) * [ (+3 & –) ]**

+3 (P3)

DC bus terminals

+1 (P1)

– – – – –

(+1 & –) [ (+3 & –) ]**

x

Power supply output for

y

– – – – –

options (220 Vac, 30 VA)

G (E)

Ground terminal (100 ohms or less)

SECTION A. 230V

FUNCTION

TERMINAL

1 - 10HP (CT) 15 - 30HP (CT)

40 - 100HP (CT)

SECTION B. 460V

FUNCTION

TERMINAL

1 - 10HP (CT) 15 - 20HP (CT) 25 - 60HP (CT) 75 - 400HP (CT)

Table 1-2. Terminal Functions and Voltages of Main Circuit

– – – – – indicates that terminals are not present.

* For installation of DB (Dynamic Braking) Units, see Appendix 7.

** indicates terminal marking or connection difference for units with "L" in Model No.

( "L" ) (04/27/95)