background image

ƒ auto—Enables auto-negotiation of Flow Control.

ƒ on—Enables Flow Control.

ƒ off—Disables Flow Control.

ƒ rx—Enables receiving pause frames only.

ƒ tx—Enables transmitting pause frames only

Default Configuration

Flow Control is off.

Command Mode

Interface configuration (Ethernet, port-channel) mode

User Guidelines

Flow Control will operate only if duplex mode is set to FULL. Back Pressure will operate only if duplex

mode is set to HALF.

When Flow Control is ON, the head-of-line-blocking mechanism of this port is disabled.

If a link is set to NOT use auto-negotiation, the other side of the link must also be configured to not use

auto-negotiation.

To select auto, ensure negotiation for Flow Control is enabled.

Example

In the following example, Flow Control is enabled on e5.

Console(config)# interface ethernet e5

Console(config-if)# flowcontrol on

5.7.9 mdix

The mdix interface configuration command enables automatic crossover on a given interface. To disable

automatic crossover, use the no form of this command.

Syntax

mdix {on | auto}

no mdix

ƒ on—Manual mdix

ƒ auto—Auto mdi/mdix

Default Configuration

Automatic crossover is enabled