7 show rmon alarm, Syntax, Default configuration – PLANET WGSD-1022 User Manual
Page 253: Command mode, User guidelines, Example
5.19.7 show rmon alarm
The show rmon alarm user EXEC command displays alarm configuration.
Syntax
show rmon alarm number
number — Alarm index. (Range: 1 - 65535)
Default Configuration
This command has no default configuration.
Command Mode
User EXEC mode
User Guidelines
There are no user guidelines for this command.
Example
The following example displays RMON 1 alarms.
Console# show rmon alarm 1
Alarm 1
-----------
OID: 1.3.6.1.2.1.2.2.1.10.1
Last sample Value: 878128
Interval: 30
Sample Type: delta
Startup Alarm: rising
Rising Threshold: 8700000
Falling Threshold: 78
Rising Event: 1
Falling Event: 1
Owner: CLI
The following table describes the significant fields shown in the display:
Field
Description
OID
Monitored variable OID.
Last Sample Value
The statistic value during the last sampling period. For example, if the sample