Positioning and control functions

Preparatory instructions

101

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

8.4.12 Preparatory instructions

The following command combinations are preparatory instructions for creating
speed step profiles or setting comparator switch points . The prepared positioning
process is started using POSA or POSR. Note the following:

Combined commands can be mixed (POSR SPEED, POSR OUTPUT).

A total of 8 combined commands can be programmed per positioning process.

The positioning values of the command combinations are always positive and

refer to the start point of the positioning process. They represent differences in
travel. The direction is specified by the next positioning command. This can be
relative (POSR) or absolute (POSA) . Meaning:

The positioning values for speed steps, ramp times or comparators always apply

from the point at which positioning starts (for POSA and POSR)

The positioning values for speed steps, ramp times or comparators are numerical

values:

If the following positioning is positive, COMPAX calculates them as positive

values.

If the following positioning is negative, COMPAX calculates them as negative

values.

If a process cycle has been interrupted by "Stop", continue the cycle using

"Start".

The preparatory instructions are canceled by the "Hand+/-", "Find machine zero"

and "Approach real zero" commands.

8.4.13 Changes in speed within a positioning process [POSR SPEED]

Each speed step profile can have a maximum of 8 speed steps. The comparator
value is specified as a relative dimension. It is referenced to the positioning start
point.

POSR value 1 SPEED value 2
Value 1: only positive values permitted (unit corresponds to P90); two digits after

the decimal point (three for inches), a control parameter (P40..P49) or a
variable V1 ... V39.

Value 2: no digits after the decimal point; numerical value, a control parameter

(P40..P49) or a variable V1 ... V39.
e.g.: POSR .P40 SPEED .P41

N001: ACCEL 250

Acceleration and braking time = 250 ms

N002: SPEED 20

Starting velocity = 20%

N003: POSR 150 SPEED 30

1st speed step when starting position

±

150, sets velocity to

30%.

N004: POSR 300 SPEED 50

2st speed step when starting position

±

300, sets velocity to

50%.

N005: POSR 500 SPEED 80

3st speed step when starting position

±

500, sets velocity to

80%.

N006: POSR 900 SPEED 60

4st speed step when starting position

±

900, sets velocity to

60%.

N007: POSA -1000

Positioning command to position -1000 (position -1000 is
approached with all of or one part of the speed step profile
depending on the start point).

N008: POSR 200 SPEED 50

Prepares a new speed step profile.

N009: ...

POSR SPEED

Syntax:

Example:

Advertising