To include the actual position in a calculation, for example, you may assign as
follows:

N100: V030=S1
or
N100: V030= S1 + 10

The variable V030 derived in this way can be used later, for example, in a
positioning instruction as a preset target.

After Power On, the variables retain the old value as before Power Off as they are
stored in the ZPRAM. With the special instruction V000=x, all variables (on the cam
controller settings) are set to the value x.

Writing convention of variables (V0-V39) and control parameters (P40-P49)

For reasons of compatibility, a preceding point (full stop) is expected in the syntax for motion commands:
e.g.: POSA .P40, ACCEL .V10
The new comparison and arithmetic commands will operate without a preceding point (full stop): e.g.:
P41=V10+S1, IF V20 > S2 GOTO 10

Read status and
assign variables

Initializing
variables:

POSA

POSR

SPEED

ACCEL

OUTPUT

Password

SPEED

SYNC

Mark

reference

POSR

SPEED

POSR

OUTPUT

Cam

controller

WAIT

GOTO

GOSUB

RETURN

END

REPEAT

IF I..

Comparison

WAIT Start

GOTO /

GOSUB EXT

IF Error/ Stop

Arithmetic

Position

monitoring

Idle display

Speed

monitoring

Engage /

disengage

brake / final

stage

Variable

voltage