Operating instructions, Compax-m / -s, Square of peak motor current – Parker Products COMPAX-M /-S (L) User Manual

Page 134: Optimization display 134, Use the effective value

Advertising
background image

Operating Instructions

COMPAX-M / -S

Optimization display

134

x

t

x

x

t

acceleration phase

decerleration phase

speed
set
point

actual
value
of
position

time needed for positioning

actual
value
of
position

max. backshoot with
ref. to max. position

actual
value
of
position

max. position overshoot

1

4

5

6

max. position overshoot

P14

t

t

x

t

t

t

t

7

8

9

10

13

14

2

x

b

n

I

q

max. acceleration tracking error

max. acceleration speed

pos. current limit

time in pos. current limit

neg. current limit

time in neg. current limit

max. deceleration tracking error

max. deceleration speed

U

ZW

2 . U

main

max. intermediate voltage

You will find a complete status list on Page207.

Reference value: 80 000A

2

The maximum peak current of a motor phase is continually determined once
COMPAX is switched on and this is stored as status S13 or S14 using
P233/234=56.
This display is generated as long as the motor is powered. The value is reset when
COMPAX is switched off (after "OFF").

Obtaining the peak motor current using S13 (P233=56) as an example:

2

max

A

000

80

*

13

S

I

=

Use the effective value

I

I

eff

=

max

2

to calculate the peak load within the motor cycle.
If this value rises to 1.5 times the peak current of the system, error E41 is triggered.
You will find more detailed explanations on the limiting characteristics of COMPAX
on Page 222.

Square of peak
motor current

Advertising