Technical data, Interfaces, Bus connection: optional – Parker Products COMPAX-M /-S (L) User Manual

Page 65

Advertising
background image

Technical data

65

Unit

hardware

Connector

assignment / cable

Technical data

Configuration

Positioning and

control functions

Optimization

functions

Interfaces

Accessories /

options

Status

Parameter

Error list

0.8A for the other units (incl. NMD).

Digital outputs, each 100 mA.

If needed, for fan approx. 100 mA.

For motor holding brake (0.35A-1.6A).

If needed, absolute encoder: 0.3A.

Accuracy

Positioning on the motor shaft:

Resolution: 16 bits (= 0.3 minutes of angle)
Absolute accuracy: +/-15 minutes of angle

Maximum power dissipation

COMPAX 10XXSL: ...................... 50W

COMPAX P1XXM: ..................... 140W

COMPAX 02XXM / NMD10/20: . 120W

COMPAX 05/10/15XXM: ........... 250W

COMPAX 25XXS: ....................... 80W

COMPAX 45XXS/85XXS:.......... 170W

COMPAX 35XXM: ..................... 610W

Data record memory

250 data records, protected from power failure.
Data record functions

Positioning commands, I/O instructions, program

commands:
ACCEL, SPEED, POSA, POSR, WAIT, GOTO,
GOSUB, IF, OUTPUT, REPEAT, RETURN, END,
WAIT START, GOTO EXT, GOSUB EXT, SPEED
SYNC, OUTPUT A0, GOTO, POSR SPEED,
POSR OUTPUT , +, -, *, /.

Target value generator

Ramps: linear, quadr., smooth; 10ms...60s.

Travel specified in increments, mm, inch or

variable using a scaling factor.

Monitoring functions

Mains power/auxiliary control voltage.

Motor and final stage temperature/blocking

protection.

Tracking error monitoring.

Ready contact: 0.5A; 60V; 30W.

Ambient conditions

Temperature range: 0...45°C.

Max. relative air humidity as per DIN 40040 class

F (

75%); no condensation.

Interfaces

Control inputs: 16 (8 for COMPAX 1000SL)

24V DC, 10 kOhm (see ex page 52).

Control outputs: 16 (8 for COMPAX 1000SL)

active HIGH, short circuit protected; 24V (see ex

page 52).

RS 232

9600 baud or 4800 baud

(for COMPAX 1000SL, fixed at 9600 baud).

Length of words 8 bits, 1 start bit, 1 stop bit.

Software handshake XON, XOFF.

Programmable controller data interface

(excluding COMPAX 1000SL)

via 5 binary inputs and outputs.

Encoder interface (option; standard for

COMPAX 1000SL)

Encoder emulation: 512 or 1024 counts/rev

Encoder input: RS422 interface; supply: 5V 120-

10000 lines/rev

COMPAX 1000SL signal interfaces
(optional)

Encoder emulation or

encoder input or

step/direction input or

analogue input

±

10V

Absolute value sensor interface (option A1)

(excluding COMPAX 1000SL)

Supply voltage: 24V+/-10%.

Sensing code: grey code, single step.

Direction of counting: in clockwise direction when

looking at the shaft: rising.

Data interface: RS422 /24 bit data format (start:

MSB).

Cycle frequency: 100 kHz.

SinCos

(option S1/S2/S3)

High-resolution encoder instead of resolver.

Single-turn or multi-turn (absolute value over 4096

motor revolutions).

Option S2 with multi-turn: absolute value sensor

with programmable transmission factor.

Option S3 for linear motors.

HEDA: synchronous, serial real time

interface

Included in option A4 or option A1.

Bus connection: optional

dc-insulated bus connection.

RS485

Max. 115k baud

2 or 4 wire/RS485

Interbus S

2-conductor remote bus

500 kBaud.

max. 64 participants per ring.

Profibus

1.5 MBaud

Sinec L2-DP and FMS.

Advertising