Appendix, Compax-m/s – Parker Products COMPAX-M /-S (L) User Manual

Page 214

Advertising
background image

Appendix

COMPAX-M/S

COMPAX standard parameters

214

No.

Meaning

Unit

Minimum
value

Default
value

Maximum
value

Valid
from...

P20

RS232 handshake Software handshake

"0": without
"1": with XON, XOFF

Power on

P20 setting.
The sum of the
specified values is
entered in P20.

Error transmission /
negative command
acknowledgement
(E90 - E94)

"0": Error only with interface activity and if

the transmitted command triggers an
error.

No neg. command acknowledgement

(E90 - E94).

"2": no transmission of error and no neg.

command acknowl. (E90 – E94).

"4": Messages are indated for errors and

neg. command acknowl. (E90 – E94)
as soon as th. occur w. Exx

C

R

L

F

>.

"6": errors & neg. command acknow.

(E90 – E94) only with interface
activity.

immediat.

End sign selection

"0":

C

R

L

F

>

"8":

C

R

Power on

Binary transfer

"0": without

"16": with

immediat.

BCC: block check
EXOR via all signs apart
from the end sign

"0": without

"128": with

Power on

P21

Factor for influencing the travel per motor
revolution

0.1000

1.0000

10.0000

VP&VC

P22

Factor for modifying the speed which is
allocated to speed SPEED 100%.

52

0.5000

1.0000

2.0000

VP&VC

P23

Stiffness of drive

%

10

100

5000

VP

P24

Speed controller damping

%

0

100

500

VP

P25

Speed – advance control value

%

0

53

100

500

VP

P26

Acceleration – advance control value

%

0

100

500

VP

P27

Moment of inertia

%

10

100

500

VP

P29

Machine zero comparison

Degre
e

0

0

360

VP

P35

Switch on mark reference

"0": switched off

"1": switched on

VP

P36

Limitation of speed correction value for external
position adjustment (only COMPAX XX00 and
COMPAX XX30) ="0": switched off

% of
nominal
speed
(P104)

0

0

100

VP

P37

Minimum travel to mark

corr.. P90

0.00

0.00

<P38

VP

P38

Maximum travel to mark

corr.. P90

>P37

0.00

4 000 000.00

VP

P39

Maximum feed length

corr..P90

P38

0.00

<P11 or P12

VP

P40

Control parameters

-4 000 000

0

+4 000 000

immediat.

P41

Control parameters

-4 000 000

0

+4 000 000

immediat.

P42

Control parameters

-4 000 000

0

+4 000 000

immediat.

P43

Control parameters

-4 000 000

0

+4 000 000

immediat.

P44

Control parameters

-4 000 000

0

+4 000 000

immediat.

P45

Control parameters

-4 000 000

0

+4 000 000

immediat.

P46

Control parameters

-4 000 000

0

+4 000 000

immediat.

P47

Control parameters

-4 000 000

0

+4 000 000

immediat.

P48

Control parameters

-4 000 000

0

+4 000 000

immediat.

P49

Control parameters

-4 000 000

0

+4 000 000

immediat.

52

When motor nominal speeds have been modified, use this factor to perform a simple adaptation to the

current program.

53

When P93 = 4, P25 must be >0.

Advertising